On a phone, pinch to zoom or turn the phone sideways.

Operation

Installation, lubrication and maintenance – TSN 030 444 worm geared motors

Installation
Inspect the gearbox and remove the preservative.
Mount it on a machined surface with roughness Ra 6.3 and flatness 0.1 mm – only in the position it is intended for.
When connecting to the machine via a coupling, make sure the shafts are aligned.
Fit pulleys, wheels and couplings with mounting tools – never by hammering.
Electrical connection
Connect the motor according to its wiring diagram and earth it properly.
The voltage on the motor nameplate must match the mains voltage.
Protect the motor with fuses or a circuit breaker; after long storage check the winding insulation.
Cooling air must have free access to the motor.
Lubricationstandard: lifetime filling

In production we fill the gearboxes with a permanent filling – the grease Shell Tivela Compound A, unless agreed otherwise. The filling lasts the whole life of the gearbox and needs neither changing nor checking.

SizeTSN 50TSN 63TSN 80
Grease filling0.230.400.85 – 1.2

Gearboxes for oil filling have a filler, drain and level hole – the level hole determines the required quantity. Check the oil level before start-up.

Oil filling – on request
ISO VGWhen
220input shaft below, ambient below 20 °C, input speed above 1.400 rpm
320 · 460input shaft above, higher ambient temperature, lower speeds
680input speed below 300 rpm
Running-in and maintenancehousing temperature max. 80 °C
30 hrunning-in – load raised gradually from 50 % to full
300 – 500 hthe gearbox reaches its catalogue ratings
500 hfirst oil change – oil filling only
3.000 – 4.000 heach further oil change, depending on the oil
In operation, watch
tightness, especially of the shaft seals
temperature rise – housing surface max. 80 °C
any sudden increase in noise, and tightness of the mounting bolts
Safety and storage
In operation the gearbox surface can exceed 70 °C.
Store dry, dust-free and without sudden temperature changes.
The corrosion protection lasts for 6 months of storage.

Send an enquiry for this item

Tell us the size, ratio, shaft end position, mains voltage and quantity – we will prepare a quotation or help you choose.

Send an enquiry