On a phone, pinch to zoom or turn the phone sideways.
Type E
Input for IEC motors – TS 031 444 worm gearboxes
Instead of a free input shaft, type E has a flange for a three-phase IEC induction motor in design IM B14 (IM 3681) – with a small flange. The motor shaft is connected to the worm via a coupling inside the flange. We supply motors for the voltage and frequency you order, with a brake on request; for speed control we supply a frequency inverter.
Matching motorsby ratio
| u | TS 50IEC | flange | TS 63IEC | flange | TS 80IEC | flange |
|---|---|---|---|---|---|---|
| 10 | 71 · 80 | 85 · 100 | 80 · 90 | 100 · 115 | 90 | 115 |
| 16 | 71 · 80 | 85 · 100 | 80 · 90 | 100 · 115 | 90 | 115 |
| 20 | 71 · 80 | 85 · 100 | 80 · 90 | 100 · 115 | 90 | 115 |
| 25 | 71 | 85 | 80 · 90 | 100 · 115 | 90 | 115 |
| 31.5 | 71 | 85 | 80 · 90 | 100 · 115 | 80 · 90 | 100 · 115 |
| 40 | 71 | 85 | 71 · 80 | 85 · 100 | 80 · 90 | 100 · 115 |
| 50 | 63 · 71 | 75 · 85 | 71 · 80 | 85 · 100 | 80 · 90 | 100 · 115 |
| 63 | 63 · 71 | 75 · 85 | 71 · 80 | 85 · 100 | 80 · 90 | 100 · 115 |
| 80 | 63 · 71 | 75 · 85 | 71 · 80 | 85 · 100 | 80 · 90 | 100 · 115 |
B14 flangedimensions in mm
| IEC | flange | Mpitch circle | Nspigot | Pouter ⌀ | thread | motor shaftd × l |
|---|---|---|---|---|---|---|
| 56 | FT 65 | 65 | 50 | 80 | M5 | 9 × 20 |
| 63 | FT 75 | 75 | 60 | 90 | M5 | 11 × 23 |
| 71 | FT 85 | 85 | 70 | 105 | M6 | 14 × 30 |
| 80 | FT 100 | 100 | 80 | 120 | M6 | 19 × 40 |
| 90 | FT 115 | 115 | 95 | 140 | M8 | 24 × 50 |
Flanges FT 65 to FT 115 correspond to the small IEC flange (C flange) of the given motor size. Overall dimensions depend on the motor manufacturer – a drawing with a specific motor is available on request.
Send an enquiry for this item
Tell us the size, ratio, type, mounting, mounting position and quantity – we will prepare a quotation or help you choose.