Standard cylindrical inductive sensors with M12×1 or M18×1 thread. The sensors must be flush-mountable; another type can be specified by the customer in the order.
| TMP | Amin | Bmin | C | F2 | S | TM12×1 | TM18×1 |
|---|---|---|---|---|---|---|---|
| 25 | 45 | 45 | 60 | 32 | 28 | 10 | 20 |
| 32 | 45 | 45 | 60 | 42 | 37 | 10 | 20 |
| 45 | 45 | 45 | 60 | 50 | 44 | 15 | 20 |
| 63 | 55 | 50 | 75 | 65 | 58 | 15 | 20 |
| 71 | 60 | 50 | 75 | 90 | 82 | 15 | 20 |
| 80 | 65 | 60 | 75 | 120 | 108 | 20 | 20 |
The trigger ring has diameter S and width T; set the sensor spacing to stroke + T. Distance A depends on the KA adapter, BL bars or housing mounting and is adjusted as required. The sensors sit in sliding holders – slots in the cover allow adjustment of about 10 mm in both directions. Set distance U from the ring according to the sensor sensitivity; the sensor face must not protrude into the cover. Standard orientation matches the motor – position 2 or 4.
| TMP | L |
|---|---|
| 25 | 56 |
| 32 | 53 |
| 45 | 62 |
| 63 | 85 |
| 71 | 94 |
| 80 | 132 |
A ring at the end of the screw prevents it from being unscrewed. It must not be used as a fixed stop.
Types N and VS are supplied with a lead screw cover as standard. If no cover is required, state NC in the order. In dusty environments protect the screw with MA bellows (page 26) or clean it more often.