Design

Sizing the screw jack – TMP worm gear screw jacks

The size is determined by the required axial force, the duty cycle and operating conditions; with linked units, by the most heavily loaded unit. Confirm the choice by checking buckling and critical speed (page 29).

Duty cycle and temperaturemax. surface temperature of the unit 80 °C
0.00.10.20.30.42030405060708090100duty cycle h [%]temperature factor ft807163453225
FskFmax = vmaxv · ft · fT
Fskactual axial force, Fmax – max. force of the unit [kN]
vlifting speed, vmax = 2 800 mm/min (TMP 80: 1 500)
ftduty cycle factor (chart), fT – ambient temperature factor
h = tztz + tp · 100 [%]

tz – lifting and lowering time per hour, tp – rest time.

Tu [°C]<10203040506070
fT1.1810.830.670.50.330.16

With MA bellows reduce the duty cycle by about 25 % – bellows limit heat dissipation.

Drive torque
Mk = 50 · F · zπ · η + Mo

Mk [Nm]; F [kN]; z – stroke per revolution (SP 1 mm, L 0.25 mm); η [%]; Mo – no-load torque (page 03). The breakaway torque can be considerably higher, especially after a long standstill. The motor starting torque must not exceed Mk max.

Self-lockingbronze nut, steel screw
TMP 25Tr 18×4TMP 32Tr 20×4TMP 45Tr 30×6TMP 63Tr 40×7TMP 71Tr 55×9TMP 80Tr 80×10
lead angle γ [°]4.5504.0464.0463.4933.2472.430
pitch diameter d2 [mm]16.018.027.036.550.575.0
self-locking at restnoconditionallyconditionallyconditionallyconditionallyyes

Efficiency when lowering is decisive. With a lead angle of 2.5° to 4.5° self-locking is only conditional (vibration, shocks) – if in doubt, use a brake on the input. Standard units are not dynamically self-locking; allow for overrun when stopping in the screw length.